Danfoss has a leadership position in the field of commercial refrigeration by continuously providing innovative components that are energy efficient and environmentally-responsible, especially when it comes to the use of refrigerants. The portfolio consists of a full range of components that are engineered to deliver the best value over the longest period of time.
Danfoss customize components to meet the unique needs of individual commercial refrigeration OEM customers and offer off-the-shelf products and parts used by installers, contractors and hundreds of other small businesses within the commercial refrigeration industry.
• Direct or servo operated valve for liquid, suction and hot gas lines with fluorinated refrigerants.
• Supplied as complete or separate components. Valve body, coil and flanges, to be ordered separately.
• Applications: Refrigeration, Freezing & Air Conditioning Plants.
• Designed for upto 105°C.
• Connections: Flare upto 5/8” & Solder upto 21/8”
• Available in stainless steel, gas-powered and pulse solenoid.
• Specifically designed to operate in aggressive environments with high humidity and temperature fluctuations found in most refrigeration systems.
• Clip-on coils available for the entire range of Danfoss Solenoid Valves for refrigeration, freezing and air conditioning applications.
• Entire range consists of Solenoid Expansion Valves and Stepper Motor Expansion Valves, including versions for CO2 systems.
• Makes it possible to keep up with the increasing environmental concerns and tighter CO2 emission regulations.
• Significant energy savings and cost reductions.
• Serves different functions in both Commercial & Industrial Refrigeration and Air Conditioning applications.
• Range contains Liquid Distributors, Pilot & Motorized Valves, Oil Regulating and Overflow Valves.
• Capacity, Crankcase Pressure and Receiver Pressure Regulation.
• Covers a wide range of applications within Refrigeration and Air Conditioning.
• Available in two categories: KP (standard) and RT (heavy duty).
• Switches can be delivered for fluorinated refrigerants as well as ammonia.
• Range covers both Hermetic Filter Driers and Filter Driers with Exchangeable Core.
• Hermetic Filter Drier covering functions suitable for – Standard, Bi-flow, Receiver and Burn-out functions.
• Filter Driers with Exchangeable Core include: Standard Core for CFC/HCFC and HFC, Burn-out Core and Mechanical Filter.
• Material: Danfoss Sight Glass SG/SGR, SGI/SGRI, SGN/SGRN.
• Refrigerants: R22, R134a, R404a, R407C, R507, R407A, R407F, R448A, R449A, R450A, R452A, R513A.
• From 1/4″ – 7/8″.
• Available with Flare, Solder and Socket connections.
• SGN/SGRN (with N type indicator) can be used with almost all refrigerants.
• Maximum working pressure: 35 Bar/500 Psig (media temp: 50° – 150°).
• Material: Danfoss Shut-off ball valves for Refrigeration, GBC.
• Refrigerants: R134a, R22/R407C, R404a/R507, R407A. R407F, R410A, R448A, R449A, R450A, R452A, R513A.
• From: 1/4 ” to 3 1/8″ connection (solder/flare).
• Available with and without access port.
• GBC 6s to GBC 25s can be used with R 32.
• Maximum working Pressure: 45 Bar/650 Psig (media temp: – 40° to 150°).
• Complete electronic system developed for monitoring and optimizing any Commercial & Industrial Refrigeration and A/C system.
Features and benefits:
• Great reliability proved through millions of installations all over the world.
• Electronic controls for almost any commercial refrigeration application.
• One-stop-shopping, all you need from one supplier.
• Pressure operated water valves are used for regulating the flow of water in refrigeration plants with water-cooled condensers.
• Gives modulating regulation of the condensing pressure and maintains it at a constant during operation.
• When the refrigeration plant is stopped, the cooling water flow shuts-off automatically.
• Ensures oil returns to the compressor oil sump.
• Prevents compressor breakdown caused by lack of lubrication.
• Increases compressor operating life.
• Protects against liquid hammer in the compressor.
• Provides better utilization of condenser and evaporator capacity (no oil-gas collection).
• Optimize the heat transfer in HVAC, District energy and freshwater systems with brazed, gasket and welded heat exchangers or freshwater distillers.
• Availability: Innovative MPHE and Traditional BPHE.
• Gasket heat exchangers can be fully customized to meet your requirements. Choose between traditional, semi-welded, free flow, sanitary plate heat exchangers and evaporators & condensers.
• Electronic Temperature Sensors
• Pressure Transmitters, Liquid Level Control Transmitters and Gas Detection Sensors
• Suitable for electronic control or refrigeration applications.
• Suitable for home appliance and light commercial industries.
• Product range includes CFC-free electro-mechanical thermostats for refrigerators and freezers.
• Certified in accordance with ISO 9001/ISO 14001 standards with production plants in Slovakia.
• Specifically designed for protection of components against excessive pressure.
• Meets strict quality demands and safety requirements for Industrial Refrigeration installations specified by International Classification Societies.
• Valves available with Internal (T2) or External (TE2) pressure equalization.
• Refrigerant availability: R22/407, R404/507, R134a, R407a
• Ordering Codes: 068Z3209, 068Z3403, 068Z3348, 068Z3501
• Connection: 3/8” X 1/2” (flare)
• Capillary: 1.5m
• Compatible Orifice: No .00 to 06
• Available with Internal (T2) or External (TE2) pressure equalization.
• Refrigerant availability: R22/407, R404/507, R134a, R407c
• Ordering Codes: 068Z3206, 068Z3400, 068Z3346, 068Z3496
• Connection: 3/8” X 1/2” (flare)
• Capillary: 1.5m
• Compatible Orifice: No .00 to 06
• Available in: MOP, Solder and other options.
• Available in: Flare/Solder/Flange type (Straight/Angle Way).
• Available in different connections.
• Available for Expansion Valves TE 5/TE12/TE20/TE55 models.
• Available in MOP, Solder and other options.
• Flow Direction is single-flow angle way.
• Flow direction indicator is embossed 1-way arrow.
• Material: Expansion Valve
• Available Ranges: TGE 10, TGE 20 , TGE 40
• Refrigerant: R22/R134a, R404a , R507, R407C, R410a
• Application: Air conditioning, heat pump, water chiller, refrigeration containers and traditional refrigeration system.
• MOP function models also available.
• Can be used up to 47TR (R407 by exchanging Orifice & Elements).
• Available in MOP, Solder and other options.
• Thermostatic expansion valves are used for liquid injection into evaporators on both refrigeration and air conditioning systems using fluorinated refrigerants. Its supplied as a parts program with a wide range of valve bodies.
• Exchangeable Orifice
• Regulates the injection of refrigerant liquid into evaporators.
• Temperature range from –60°C to 50°C
• Rated capacity: 0.5 to 1890 kW (R 22)
• Material: Industrial Solenoid Valve
• Type: EVR 220B, EV210A, EV210B, EV220A, EV224B, EV250B, EV20B, EV310B, EV212B, EV220W
• Applications: Laundry & Dry Cleaning, Industrial Washing , Autoclaves/Sterilizers, Compressor & Vacuum Pumps, Plastic Molding Machinery, Steam Boilers, Food Processing , Sprinkler & Firefighting System, Dentist Equipment, Coffee Machines & Boilers, etc.
• Available with: Solder/Flare connections, NO/NC functions and other options.
• Material: Low Pressure Control
• Type: KP 1
• Fitted with a single-pole, double-throw (SPDT) switch.
• Range: 0.2 to 7.5 Bar
• Diff: 0.7 to 4 Bar
• Available in: IP30, IP44 & IP55 enclosures
• Type availability: Automatic & Manual
• Material: High Pressure Control
• Type: KP 5
• Fitted with a single-pole, double-throw (SPDT) switch.
• Range: 8 to 32 Bar
• Diff: 1.8 to 6 Bar
• Available in: IP30, IP44 & IP55 enclosures
• Type availability: Automatic & Manual
• Material: Dual Pressure Control
• Type: KP 15
• Fitted with a single-pole, double-throw (SPDT) switch.
• Range: -0.2 – 7.5 Bar & High 8 to 32 Bar
• Diff: 0.7 to 4 Bar & 4 Bar
• Available in: IP30, IP44 & IP55 enclosures
• Type availability: Automatic & Manual
• Material: Dual Pressure Control
• Type: KP 61 upto KP 98
• KP Thermostats are single-pole, double-throw (SPDT), temperature-operated electric switches.
• Range: Upto 160°C
• Capillary Length: Upto 5m
• Type availability: Automatic & Manual
• Application: Deep Freeze, Refrigeration & Air Conditioning Plants.
• Available with different temperature ranges and capillary sizes.
• Material: Industrial Pressure Control
• Type: KP, KPI, BCP, CAS, CS, KPS, MBC 5100, MBC 5180, RT, MBC 8100
• Accurate, robust, built for long life and performs flawlessly even under the harshest conditions.
• Applications: Marine & Railway, Industrial Boiler & Boiler Room, Autoclaves & Sterilizers, Water Pump & Hydraulic Equipment and Windmills.
• Available with different ranges, pressure settings and applications.
• Material: Industrial Temperature Control
• Type: CAS, KPS, RT
• Includes temperature controls for General Industrial and Light Industrial applications, controlling air and water.
• Reliable electro-mechanical controls components.
• Applications: covers most Industrial applications.
• Available in different ranges and types of capillaries, as well as rigid and armed capillary tubes.
• Material: ELIMINATOR® Filter Drier DCL
• For applications requiring high moisture & acid adsorption capacity.
• Features: 80% 3A molecular sieve with 20% activated alumina.
• Recommended to use with: HFO, HC, HFC & HCFC refrigerants.
• Available connection: 1/4″ up to 11/8″ (Flare & Solder)
• Available with different lengths as per the drying capacity.
• Material: ELIMINATOR® Filter Drier DML
• Features: 100% 3A molecular sieve core
• High drying capacity minimising the risk of acid formation
• Available connection: 1/4″ up to 11/8″ (Flare & Solder)
• Available with different lengths as per the drying capacity.
• Material: ELIMINATOR® Filter Drier Core 48 DC
• Features: 80% molecular sieve & 20% Al2 O2
• DC core contains active alumina which is polar used for acid absorption.
• Used for: R134a, R404a, R507, R407C, and R410a, HFO & HCFC
• Used for Oil: Mineral or AB, POE or PAG pure
• Material: ELIMINATOR® Filter Drier Core 48 DM
• Features 100% molecular sieve
• Used for: R134a, R404a, R507, R407C, and R410a, HFO & HCFC
• Used for Oil: Mineral or AB, POE or PAG pure, POE or PAG additives
• Material: ELIMINATOR® Filter Drier Shell DCR
• Connection: From 5/8″ to 2 5/8″
• DM core used for: R134a, R404a, R507, R407C, R22 & R410a
• Used for Oil: Mineral or AB, POE or PAG pure, POE or PAG additives.
• Material: Check Valve NRV & NRVH
• Ensures correct flow direction.
• Available in: Straight & Angle way versions.
• Hermetic tight design for solder versions.
• Material: Pressure Transmitter
• Segments: Transportation, Heating & Sanitation, Machine & Equipment Energy.
• Can be used up to 125°C.
• Available with various setting ranges and connections.
• Approvals: Marine, ATEX & UL Hazloc